Products
Gas Analyzer Pumps
adi-ir-logo.png
Back to the product list

J-Series Dia-Vac® Pump Elevated Head (General Purpose)

The J-Series Dia-Vac® Elevated head pump is an alternative to the electrically heated version.

With the ultra strong G-10 spacer; the 316 stainless steel pump head can be mounted into a heated enclosure while the pump motor remains outside at ambient temperature. Maximum permissible temperature for the pump head is 200°C (400°F).

*Note that the elevated J-Series Dia-Vac® is only available with a .140 eccentric (J141).

Available options 1

ADI’s gas sampling Dia-Vac® Pumps can pass your gas at the speed of need! Due to an increased interest in reducing the pressure, vacuum, and/or flow on the Dia-Vac® pumps, our engineers designed a modified eccentric design. This allows you to customize your Dia-Vac® pump to meet your application requirements while at the same time increasing the diaphragm and bearing life. The standard eccentric size is 0.160 on the J-Series Dia-Vac® Pump.

Please note that the chart below is not meant to be read as a combination of pressure and vacuum at the same time, only pressure or vacuum.

 

J-Series Dia-Vac®

Flow Averages

(Please click on individual Model # for actual performance curves)

 

Model #

PSIG (Max Pressure)

Bar Gauge (Max Pressure)

InHg Gauge (Ultimate Vacuum)

Mbar Gauge (Ultimate Vacuum)

SCFM (Max Flow)

SLPM (Max Flow)

 

J081

10.5

0.7

16.4

555

0.24

6.7

J081.pdf

J081-Metric

      J081_Metric.pdf

J101

14.5

1

19.2

650

0.31

8.8

J101.pdf

J101-Metric

      J101_Metric.pdf

J121

20.9

1.44

21

711

0.37

10.6

J121.pdf

J121-Metric

      J121_Metric.pdf

J141

25

1.72

22

745

0.44

12.5

J141.pdf

J141-Metric

      J141_Metric.pdf

J161

31.1

2.14

24.4

826

0.49

14

J161.pdf

J161-Metric

      J161_Metric.pdf

 

Head Connection Schematics