J-Series Dia-Vac® Pump Elevated Head (General Purpose)

The J-Series Dia-Vac® Elevated head pump is an alternative to the electrically heated version.

With the ultra strong G-10 spacer; the 316 stainless steel pump head can be mounted into a heated enclosure while the pump motor remains outside at ambient temperature. Maximum permissible temperature for the pump head is 200°C (400°F).

*Note that the elevated J-Series Dia-Vac® is only available with a .140 eccentric (J141).

Key Specifications

Max Pressure (psig)

10.5 - 31.1

psig

Max Vacuum (InHg)

16.4 - 24.4

InHg

Max Flow Rate (slpm)

6.7 - 14

SLPM

ADI’s gas sampling Dia-Vac® Pumps can pass your gas at the speed of need! Due to an increased interest in reducing the pressure, vacuum, and/or flow on the Dia-Vac® pumps, our engineers designed a modified eccentric design. This allows you to customize your Dia-Vac® pump to meet your application requirements while at the same time increasing the diaphragm and bearing life. The standard eccentric size is 0.160 on theJ-Series Dia-Vac® Pump.

Please note that the chart below is not meant to be read as a combination of pressure and vacuum at the same time, only pressure or vacuum.

If you're looking for head connection schematics you can find them on our dedicated page.

Flow Averages

(Please click on individual Model # for actual performance curves)

J-Series Performance — US Units

Model

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

Availability

J081

10.5

16.4

0.24

US curve / Metric curve

Standard J-Series reference

J101

14.5

19.2

0.31

US curve / Metric curve

Standard J-Series reference

J121

20.9

21

0.37

US curve / Metric curve

Standard J-Series reference

J141

25

22

0.44

US curve / Metric curve

Heated-head model

J161

31.1

24.4

0.49

US curve / Metric curve

Standard J-Series reference

 

J-Series Performance — Metric Units

Model

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge)

Max flow (SLPM)

Performance curves

Availability

J081

0.7

555

6.7

US curve / Metric curve

Standard J-Series reference

J101

1

650

8.8

US curve / Metric curve

Standard J-Series reference

J121

1.44

711

10.6

US curve / Metric curve

Standard J-Series reference

J141

1.72

745

12.5

US curve / Metric curve

Heated-head model

J161

2.14

826

14

US curve / Metric curve

Standard J-Series reference

How to Order

Use the configuration codes below to identify your required head material, diaphragm, motor and voltage. For the heated-head option, specify the 0.140-inch eccentric and review the heated-head option code. Please confirm the complete orderable model code and compatible combinations with Air Dimensions before purchasing.

How to Configure Your Pump

  1. Choose your pump capacity
    Select the eccentric size and number of heads based on your required performance.
  2. Select wetted materials
    Choose head and diaphragm materials suitable for the gas being handled.
  3. Specify motor requirements
    Identify the appropriate motor type, voltage and frequency for your installation.
  4. Review additional options
    Consider any special requirements, such as an elevated head or alternative housing orientation.
  5. Request a quote
    Share your selections with the Air Dimensions team to confirm compatibility, availability and pricing.

 

Understanding the Ordering Codes

Each section of the ordering guide represents a different pump configuration characteristic, including capacity, materials, motor specifications and optional features.

The available codes help identify the required specifications when discussing your pump configuration with our team.

Please note: Not all combinations of components and options may be available or compatible. Contact Air Dimensions to confirm the correct configuration and complete model number before ordering.

 

Category

Selection

Available codes / descriptions

Capacity

Pump style

J — J-Series

Capacity

Eccentric size

16 — 0.160 in; 14* — 0.140 in

Capacity

Number of heads

1 — Single head

Wetted materials

Head material

A — Aluminum; B — Teflon/Aluminum; F — 316 stainless steel

Wetted materials

Diaphragm

T — Teflon/EPDM; P — All Teflon

Motor

Motor type

A — General Purpose; G — XP/ATEX/IIC; P — BLDC (variable speed); T — BLDC

Motor

Voltage

A — 115 V AC; B — 230 V AC; H — 12 V DC; J — 24 V DC

Motor

Frequency

0 — N/A; 1 — 60 Hz, 1 phase; 2 — 50 Hz, 1 phase

Options

Additional features

M° — Heated head with K-type thermocouple; L — Elevated head