Products
Explosion-Proof Pumps
Gas Analyzer Pumps
Pump Selector
Product Finder
Services
Diaphragm Pump Repair Videos
Frequently Asked Questions
Head Connection Schematics
Gas Diaphragm Pump Spare Parts
Contact Us
How To Order
Applications
Mining Gas Sampling
Aquaculture Gas Sampling
Fenceline Monitoring
SCR Monitoring
Knowledge Hub
Dia-Vac® Gas Diaphragm Pump Technology
Combination Curves
Gas Sample System Design Using Diaphragm Pumps
Methods for Diaphragm Pump Selection
Standard Motors
Solution For Safe & Reliable Gas Transfer
Hydrogen-Compatible Pumps
About Us
News
Back to the product list

H-Series Dia-Vac® Double Head Gas Sampling Pump

The H-Series H302 is a double head Dia-Vac® pump for demanding gas sampling, CEMS and process-analysis systems in safe-area installations. Configure the two pump heads in parallel for higher sample flow or in series for increased vacuum capability, depending on the required response time and operating point.

The parallel configuration provides flow up to 83.3 SLPM at 60 Hz, rounded to 84 LPM in the H-Series product literature. The series configuration provides vacuum up to 29.5 inHg with lower free-flow capacity. Both arrangements support maximum pressure up to 60 psig under the applicable operating conditions.

Choose a General Purpose or TEFC motor according to the installation environment, voltage and frequency. For classified installations requiring a certified hazardous-area motor, use the dedicated H302 hazardous-area configuration.

Key Specifications

Max Pressure (psig)

30 - 60

psig

Max Vacuum (InHg)

26.7 - 29.5

InHg

Max Flow Rate (slpm)

41.1 - 83.3

SLPM

The H302 is designed for systems where faster sample transport, higher vacuum or a demanding combination of inlet vacuum and outlet pressure exceeds the practical operating point of a single head pump.

Parallel for Higher Sample Flow

Connect the two pump heads in parallel when the application requires faster sample transport or a shorter analyzer response time. At 60 Hz, the parallel arrangement provides flow up to 83.3 SLPM.

Series for Increased Vacuum

Connect the pump heads in series when greater vacuum is needed to overcome long sample lines, filters, conditioning components or other restrictions. At 60 Hz, the series arrangement provides vacuum up to 29.5 inHg and flow up to 43.4 SLPM under the corresponding test conditions.

Select for the Actual Duty Point

Maximum flow, vacuum and pressure values are measured under different operating conditions and should not be interpreted as simultaneous performance. Select the arrangement using the required flow at the actual inlet vacuum and outlet pressure. 

For lower-flow applications, compare the H-Series H301 Single Head gas sampling pump before selecting the H302 solely by its maximum flow.

Use the H302 performance curves to compare the parallel and series arrangements at the required operating conditions.

  • Parallel, 60 Hz: up to 83.3 SLPM, 27.1 inHg vacuum and 60 psig maximum pressure.
  • Series, 60 Hz: up to 43.4 SLPM, 29.5 inHg vacuum and 60 psig maximum pressure.
  • Parallel, 50 Hz: up to 69.1 SLPM.
  • Series, 50 Hz: up to 36.0 SLPM.

Published results are approximate and actual performance depends on the application. Use the applicable combination curve to confirm flow at the required inlet vacuum and outlet pressure. Continuous operation above 50 psig should be avoided because it may reduce diaphragm and bearing life.

Review the H-Series head connection schematics before finalizing the parallel or series arrangement.

Key specification

Recommended value

Configuration

Max Flow Rate

83.3 SLPM

H302 Parallel, 60 Hz

Max Vacuum

29.5 inHg

H302 Series, 60 Hz

Max Pressure

60 psig

Confirm flow at required pressure 

Maximum values apply to different H302 head arrangements and operating conditions. Maximum flow is achieved with the parallel configuration; maximum vacuum is achieved with the series configuration. Use the applicable performance curve to confirm the required duty point. Continuous operation above 50 psig should be avoided. 

 

Flow Averages

(Please click on individual Model # for actual performance curves)

H-Series Performance — US Units

Model

Head connection

Frequency (Hz)

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

H301

Single head

60

60

26.7

1.45

H302

Parallel

60

60

27.1

2.94

H302

Series

60

60

29.5

1.53

H302

Parallel

50

60

27.1

2.44

H302

Series

50

60

29.5

1.27

H-Series Performance — Metric Units

Model

Head connection

Frequency (Hz)

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge vacuum)

Max flow (SLPM)

H301

Single head

60

4.13

904

41.1

H302

Parallel

60

4.13

917

83.3

H302

Series

60

4.13

999

43.4

H302

Parallel

50

4.13

917

69.1

H302

Series

50

4.13

999

36.0

H301 combination curve.pdf

115 KB, PDF

H301 Flow Averages - Metric.pdf

160 KB, PDF

H302 Flow Averages-50Hz-Metric.pdf

159 KB, PDF

H302 Flow Averages 60Hz - Metric.pdf

162 KB, PDF

H302 Flow Averages 50Hz-US.pdf

129 KB, PDF

H302 Flow Averages 60Hz-US.pdf

130 KB, PDF

Configurable Double Head Arrangement

The H302 uses two adjustable pump heads that can be connected in parallel or series. The selected arrangement changes available flow and vacuum performance while retaining the same H-Series platform.

0.300-Inch Eccentric

The H302 uses the H-Series 0.300-inch eccentric. Select the pump from the published combination curves rather than treating eccentric size as a standalone indication of suitability.

316 Stainless Steel Pump Heads

The H302 is available with 316 stainless steel pump heads and configurable diaphragm options. Confirm all wetted materials against the complete gas composition, moisture, temperature and operating conditions.

Oil-Free Dia-Vac® Operation

The diaphragm design transfers the sample without oil in the pumping chamber, supporting gas-analysis systems where sample contamination must be minimized.

General Purpose and TEFC Motors

Choose the standard General Purpose motor for appropriate safe-area installations or the IP54-rated TEFC motor where a totally enclosed fan-cooled design is required. Confirm voltage and frequency before ordering.

Optional Double-Diaphragm Protection

Selected configurations may use an optional secondary diaphragm and monitorable inter-diaphragm chamber for hazardous or high-value gases. Double Diaphragm is a safety option and should not be confused with the H302 Double Head configuration.

 

  • Fast-response Continuous Emissions Monitoring Systems
  • Process gas analysis
  • Refinery and petrochemical monitoring in safe-area installations
  • Chemical-process monitoring
  • Environmental and emissions monitoring
  • Analyzer systems with long or restrictive sample lines
  • Applications requiring higher flow in parallel configuration
  • Applications requiring greater vacuum in series configuration
  • OEM analyzer systems requiring a configurable high-performance pump

How to Select the H302 Double Head Pump

  1. Define the required sample flow or response time: Identify why the available H301 Single Head operating point is insufficient.
  2. Choose parallel or series operation: Use parallel for higher sample flow and series for increased vacuum capability.
  3. Define inlet vacuum and outlet pressure: Provide the expected values at the actual duty point.
  4. Describe the sample path: Include tubing length and inside diameter, filters, probes, coolers, valves and other restrictions.
  5. Confirm the H302 operating point: Use the applicable 50 Hz or 60 Hz combination curve.
  6. Provide the complete gas composition: List all known components, concentrations, moisture and possible condensable vapors.
  7. Confirm wetted materials: Select compatible head, diaphragm and other wetted components.
  8. Select the motor: Choose General Purpose or TEFC according to the safe-area installation requirements.
  9. Confirm electrical requirements: Provide voltage, frequency and phase.
  10. Evaluate Double-Diaphragm protection: Discuss whether a monitorable secondary diaphragm is appropriate for the sampled gas.

For guidance on pressure losses, tubing and duty-point selection, review gas sample system design using diaphragm pumps

How to Order Your H-Series Pump

Use the ordering codes to identify the required head configuration, wetted materials, motor specifications and optional features. Not all combinations may be available. Contact Air Dimensions to confirm the correct configuration and model number for your application.

Category

Selection

Available codes and options

Capacity

Pump style

H = H-Series

Capacity

Eccentric size

30 

Capacity

Number of heads

1; 2 

Wetted materials

Head material

F = 316 stainless steel (316ss) 

Wetted materials

Diaphragm

T = Teflon/EPDM; P = All Teflon 

Motor

Motor type

A = General Purpose; C = TEFC; F = XP/ATEX/IIC; G = XP/ATEX/IIC; N = XP (Grp CD UL); R = XP (Grp BCD UL)* 

Motor

Voltage

A = 115 V; B = 230  

Motor

Frequency

1 = 60 Hz, 1 phase; 2 = 50 Hz, 1 phase

Options

Additional options

L = Elevated Head (1 head only); M = Heated head with thermocouple; M2 = 65°C thermostat; M3 = 100°C thermostat; M4 = 140°C thermostat; M5 = 163°C thermostat; M6 = 200°C thermostat

Ready to configure an H-Series H302 pump?

Start with the required duty point and head arrangement.

Define the duty point → Request a Quote → Confirm the H302 configuration

Review the H302 performance curves and ordering table, then select Request a Quote. Provide:

  • Required sample flow or response time
  • Parallel or series preference, if known
  • Inlet vacuum and outlet pressure
  • Gas composition and concentrations
  • Sample and ambient temperatures
  • Sample-line length and inside diameter
  • Filters and sample-conditioning components
  • Wetted-material requirements
  • General Purpose or TEFC motor preference
  • Voltage, frequency and phase
  • Double-Diaphragm requirement, if applicable

The Air Dimensions team can confirm the head arrangement, duty point, wetted materials, diaphragm, motor and complete H302 part number.

Already have a complete H-Series part number?

Include the full part number and required quantity when requesting a quote.

Not sure whether you need parallel or series operation?

Contact us, share the target flow, response time, inlet vacuum, outlet pressure and sample-path restrictions. Air Dimensions can identify the appropriate H302 arrangement from the published curves.

Related H-Series Configurations 

Need a simpler single head arrangement? 

Compare the H-Series H301 Single Head gas sampling pump when one head can provide the required operating point. 

Need a certified hazardous-area configuration? 

Review the H-Series H302 Double Head pump for hazardous areas and confirm the applicable ATEX/IECEx or UL/CSA path for the installation. 

Need a more compact higher-flow pump? 

Compare the M-Series compact Double Head gas sampling pump for lower-flow systems where installation size is the primary constraint. 

Need higher flow from a single head? 

Review the E-Series high-flow Single Head gas sampling pump for applications prioritizing the highest single-head flow in the Air Dimensions range

REACH OUT TO US