Products
Explosion-Proof Pumps
Gas Analyzer Pumps
Pump Selector
Product Finder
Services
Diaphragm Pump Repair Videos
Frequently Asked Questions
Head Connection Schematics
Gas Diaphragm Pump Spare Parts
Contact Us
How To Order
Applications
Mining Gas Sampling
Aquaculture Gas Sampling
Fenceline Monitoring
SCR Monitoring
Knowledge Hub
Dia-Vac® Gas Diaphragm Pump Technology
Combination Curves
Gas Sample System Design Using Diaphragm Pumps
Methods for Diaphragm Pump Selection
Standard Motors
Solution For Safe & Reliable Gas Transfer
Hydrogen-Compatible Pumps
About Us
News
Back to the product list

E-Series Dia-Vac® High-Flow Heated Head Gas Sampling Pump

The E-Series Heated Head Dia-Vac® pump combines high sample-flow capability with temperature control through the pump head. It is designed for hot/wet gas sampling systems where the sample must remain above its dew point before reaching downstream analytical equipment. 

Published E-Series performance includes flow up to 152 SLPM. The heated 316 stainless steel pump head is available with a K-type thermocouple, fixed thermostat or PT100 RTD to match different temperature-control requirements. 

Key Specifications

Max Pressure (psig)

15

psig

Max Vacuum (InHg)

23

InHg

Max Flow Rate (slpm)

152

SLPM

Hot/wet gas samples must remain above their dew point through the sampling system. If the sample cools inside the pump, condensation may affect the pump, sample path and analyzer performance. 

The E-Series Heated Head helps maintain the required sample temperature through the pump while supporting the higher sample flow needed for rapid transport over demanding sampling paths. 

Temperature control through the pump is only one part of the complete system. Review gas sample system design using diaphragm pumps when defining the heated line, restrictions and analyzer conditions. 

Use the E-Series combination curve to confirm flow at the actual inlet vacuum and outlet pressure. Published maximum flow, vacuum and pressure values represent different operating conditions and should not be interpreted as simultaneous performance.

 

Model #

PSIG (Max Pressure)

Bar Gauge (Max Pressure)

InHg Gauge (Ultimate Vacuum)

Mbar Gauge (Ultimate Vacuum)

SCFM (Max Flow)

SLPM (Max Flow)

 

E251

15

1

23

779

5.35

152

E251.pdf

E251-Metric

 

 

 

 

 

 

E251_Metric.pdf

 

Head Connection Schematics

Installation Guidance for Hot/Wet Sampling

Maintain the heated sample line and pump head above the sample dew point. Mount the pump with the head facing downward and position it at the highest practical point in the system to reduce the risk of liquid entering the pump head. 

Follow the E-Series Heated operating instructions and the approved system design for the selected configuration. 

The E-Series is the highest-flow single-head Dia-Vac® configuration currently published by Air Dimensions. The Heated Head version adds thermal management to the standard E-Series high-flow gas sampling pump for systems requiring both rapid sample transport and temperature control. 

  • Published flow: up to 152 SLPM
  • Published vacuum: up to 23 inHg
  • Published pressure: up to 15 psig

These maximum values represent different operating conditions and should not be interpreted as simultaneous performance. Use the E-Series combination curve to confirm flow at the actual inlet vacuum and outlet pressure. 

The E-Series Heated Head is available with different temperature-sensing and control options: 

  • K-type thermocouple
  • Fixed thermostat
  • PT100 RTD

The appropriate option depends on the required sample temperature, dew point, system controls and installation conditions. 

Contact an Applications Expert to discuss the required operating temperature, sensor, controller and electrical configuration before ordering.

Oil-Free Gas Path 

Dia-Vac® diaphragm pump technology transports the sample without lubricating oil in the gas path. 

316 Stainless Steel Pump Head 

The heated pump head uses 316 stainless steel wetted surfaces with a PTFE diaphragm in the standard published configuration. 

Continuous Gas Sampling 

The E-Series is designed for continuous gas-sampling applications such as emissions monitoring and process analysis. 

Configurable Temperature Control 

Select from K-type thermocouple, fixed thermostat and PT100 RTD options. Contact Air Dimensions to confirm sensor availability, temperature range and controller requirements for the selected pump configuration.

Continuous Emissions Monitoring 

Transport hot/wet gas samples through CEMS where rapid sample movement and temperature control are required before the analyzer. 

Process Gas Analysis 

Move heated process gas samples to downstream analytical equipment while maintaining the required temperature through the pump. 

Stack and Flue Gas Sampling 

Support extractive sampling systems where moisture and sample-path temperature must be considered. 

Refinery and Petrochemical Monitoring 

Support high-flow gas sampling in process-monitoring systems handling heated or moisture-containing samples. 

Ready to configure an E-Series Heated Head pump? Start with the application requirements. 

SIMPLE PROCESS LINE 

Define the application  →  Request a Quote  →  Confirm the configuration 

Review the E-Series performance curve, then click Request a Quote. Include the required sample temperature, dew point if known, required flow or response time, inlet vacuum, outlet pressure, sampled gas, heated-line information, preferred temperature-sensing option, voltage and frequency. 

Our Sales Team will contact you to confirm the pump, wetted materials, sensor and temperature-control arrangement. 

ALTERNATIVE PATH 

Not sure which temperature option you need? You do not need to specify the complete configuration before contacting us. Contact Us and an Applications Expert will help confirm whether a K-type thermocouple, fixed thermostat or PT100 RTD is appropriate for the system.

 

Category

Selection

Available codes and options

Capacity

Pump style

E = E-Series 

Capacity

Eccentric size

25 

Capacity

Number of heads

1 

Wetted materials

Head material

F = 316ss 

Wetted materials

Diaphragm

P = All Teflon; L = Silconert®316ss 

Motor

Motor type

A = General Purpose; F = XP/ATEX/IIC; N = XP (Grp CD UL) 

Motor

Voltage

A = 115; B = 230 

Motor

Frequency

1 = 60 1Ph; 2 = 50 1Ph 

Options

Additional options

M = Heated w/K Thermocouple

Technical note: The source lists code L (Silconert®316ss) under the diaphragm category. Please confirm the classification before publication.

How to Select the E-Series Heated Head Pump 

1. Define the required sample temperature 

Provide the sample temperature and dew point, if known. 

2. Define the required flow or response time 

Determine how quickly the sample must reach the analyzer. 

3. Define inlet and outlet conditions 

Provide the pressure at the sample point, the analyzer inlet requirements and whether the gas is vented or returned to the process. 

4. Describe the sample path 

Provide tubing length and internal diameter, heated-line temperature, filters, coolers and other system restrictions. 

5. Confirm gas and material compatibility 

Provide the gas composition, sample temperature and expected moisture or condensate. 

6. Select the temperature-control arrangement 

Indicate whether the system requires a K-type thermocouple, fixed thermostat or PT100 RTD. Air Dimensions can confirm sensor availability, temperature range and controller requirements. 

7. Confirm electrical requirements 

Provide the required voltage and frequency and identify whether the installation is a safe or classified area.

Configure an E-Series Pump for Your Hot/Wet Sampling System

Tell us the required sample temperature, dew point, flow or response time, inlet and outlet conditions, sampled gas and electrical requirements. Our team can help confirm whether the E-Series Heated Head is the right fit.

For classified installations, compare available hazardous-area gas sampling pumps and confirm the required certification before ordering.

REACH OUT TO US