How to Specify and Order Pumps from Air Dimensions Incorporated

B-Series

Capacity

Style

Eccentric

Heads

B=Micro

16

1

14

2

12

10

08

Wetted Materials

Head

Diaphragm

A=Aluminium

E=Encapsulated*

B=Teflon Coated Aluminum

P=2-Ply Teflon

F=316 SS

G=Teflon Coated 316 SS

L=SilcoNert™ 2000 316 SS

T=Solid Teflon*

Motor

Type

Voltage

Frequency/Phase

A=General Purpose

A=115

0=N/A

J†= Brush DC

B=230

1=60 Hz 1 Ph

P† = Speed Control Brushless DC

H=12

2=50 Hz 1 Ph

T= Brushless DC

J=24

Optional

Options

C=Motor Cover

L=Elevated Head

M=Heated w/ K Thermocouple

M1=Heated w/ PT100 RTD

Z=Rotate Housing 180°

*Solid Teflon Head and Encapsulated Diaphragm must be used together † 24 VDC only
Example: B161-FP-AA1 = Single Head Micro Dia-Vac® pump, 316 ss wetted parts, All-Teflon diaphragm, 115v/60Hz GP motor

J-Series

Capacity

Style

Eccentric

Heads

J=Micro

16

1

14

Wetted Materials

Head

Diaphragm

A=Aluminium

F=Telfon/Viton

B=Teflon Coated Aluminum

P=2-Ply Teflon

F=316 SS

G=Teflon Coated 316 SS

L=SilcoNert™ 2000 316 SS

Motor

Type

Voltage

Frequency/Phase

A=General Purpose

A=115

0=N/A

J†= Brush DC

B=230

1=60 Hz 1 Ph

P† = Speed Control Brushless DC

H=12

2=50 Hz 1 Ph

T= Brushless DC

J=24

Optional

Options

C=Motor Cover

L=Elevated Head

M=Heated w/ K Thermocouple

M1=Heated w/ PT100 RTD

Example: J161-AF-AA1 = Macro Dia-Vac® pump, Aluminum wetted parts, Teflon/Viton diaphragm 115v 60Hz GP motor

† 24 VDC only

M-Series

Capacity

Style

Eccentric

Heads

M=Mini

16

1

15

2

1

10

08

Wetted Materials

Head

Diaphragm

A=Aluminium

E=Encapsulated*

B=Teflon Coated Aluminum

P=2-Ply Teflon

F=316 SS

T=Teflon/EPDM

G=Teflon Coated 316 SS

H=Hastelloy C

J=Teflon Coated Hastelloy C

L=SilcoNert™ 2000 316 SS

P=Electro Polished 316 SS

T=Solid Teflon*

Motor

Type

Voltage

Frequency/Phase

C=General Purpose

A=115

0=N/A

W=Class I Division II (UL)

B=230

1=60 Hz 1 Ph

Z=ATEX Zone 2 IIC

X=N/A

2=50 Hz 1 Ph

Optional

Options

L=Elevated Head

M=Heated w/ K Thermocouple

M1=Heated w/ PT100 RTD

M2=Heated w/ 65° C Thermostat

M3=Heated w/ 100° C Thermostat

M4=Heated w/ 140° C Thermostat

M5=Heated w/ 163° C Thermostat

M6=Heated w/ 200° C Thermostat

*Solid Teflon Head and Encapsulated Diaphragm must be used together

Example: M161-FT-CA1 = Single Head Mini Dia-Vac® Pump, 316 ss wetted parts, Teflon/EPDM, 115v/60Hz General Purpose motor

R-Series

Capacity

Style

Eccentric

Heads

R=Standard

27

1

Z=Motorless

25

2

22

4

20

6

18

15

12

10

08

06

Wetted Materials

Head

Diaphragm

A=Aluminium

E=Encapsulated*

B=Teflon Coated Aluminum

P=3-Ply Teflon

F=316 SS

T=Teflon/EPDM

G=Teflon Coated 316 SS

V= Viton

H=Hastelloy C

J=Teflon Coated Hastelloy C

L=SilcoNert™ 2000 316 SS

P=Electro Polished 316 SS

T=Solid Teflon*

Motor

Type

Voltage

Frequency/Phase

A=General Purpose

A=115

0=N/A

B=High Speed

B=230

1=60 Hz 1 Ph

C=TEFC 1/3 HP

D=220/380

2=50 Hz 1 Ph

D=Air Driven

E=230/460

3=60 Hz 3 Ph

G=ATEX/IECEx IIC

X=N/A

4=50 Hz 3 Ph

F=ATEX/IECEx IIC 1/2 HP

M=TEFC 1/2 HP

N=Div 1 Gr C,D 1/2 HP

R=Div 1 Gr B,C,D 1/6 HP

Optional

Options

Options

A=416 SS Valve Discs

M1=Heated w/ PT 100 RTD

B=Head at Both Ends

M2=Heated w/ 65° C Thermostat

C=Power Cord**

M3=Heated w/ 100° C Thermostat

D=Double Diaphragm

M4=Heated w/ 140° C Thermostat

E2=Extended Head

M5=Heated w/ 163° C Thermostat

G=EPDM Gasket

M6=Heated w/ 200° C Thermostat

H=Viton Gasket

M8=Heated w/ Steam

L=Elevated Head

X=Rotate Housing 90° CW

M=Heated w/ K Thermocouple

Y=Rotate Housing 90° CCW

Z=Rotate Housing 180°

*Solid Teflon Head and Encapsulated Diaphragm must be used together

**Power cord is only available with a General Purpose motor

Example: R221-FT-AA1 = Single Head Dia-Vac pump, 316 ss wetted parts, Teflon/EPDM diaphragm, 115v/60Hz GP motor

RVA-Series Hi-Vacuum

Capacity

Style

Heads

RVA=Hi-Vacuum

1

2

4

Wetted Materials

Head

Diaphragm

F=316 SS

P=3-Ply Teflon

T=Teflon/EPDM

Motor

Type

Voltage

Frequency/Phase

A=General Purpose

A=115

0=N/A

B=High Speed

B=230

1=60 Hz 1 Ph

C=TEFC

D=220/380

2=50 Hz 1 Ph

F=ATEX/IECEx IIC 1/2 HP

E=230/460

3=60 Hz 3 Ph

G=ATEX/IECEx IIC 1/4 HP

4=50 Hz 3 Ph

M=TEFC 1/2 HP

N=Div 1 Gr C,D 1/2 HP

R=Div 1 Gr B,C,D 1/6 HP

Optional

Options

C=Power Cord

Example: RVA1-FT-AA1 = Single Head Hi-Vacuum pump, 316 ss wetted parts, Teflon/EPDM diaphragm, 115v/60Hz GP motor

H-Series

Capacity

Style

Eccentric

Heads

H=High Performance

30

1

2

Wetted Materials

Head

Diaphragm

F=316 SS

P=3-Ply Teflon

L=SilcoNert™ 2000 316 SS

T=Teflon/EPDM

Motor

Type

Voltage

Frequency/Phase

A=General Purpose

A=115

0=N/A

F=ATEX IIC 1/2 HP

B=230

1=60 Hz 1 Ph

G=ATEX IIC 1/4 HP

D=220/380

2=50 Hz 1 Ph

M=TEFC 1/2 HP

E=230/460

3=60 Hz 3 Ph

N=Div 1 Gr C,D 1/2 HP

4=50 Hz 3 Ph

R=Div 1 Gr B,C,D 1/6 HP

Optional

Options

C=Power Cord

M=Heated w/ K Thermocouple

M1=Heated w/ PT100 RTD

M2=Heated w/ 65° C Thermostat

M3=Heated w/ 100° C Thermostat

M4=Heated w/ 140° C Thermostat

M5=Heated w/ 163° C Thermostat

M6=Heated w/ 200° C Thermostat

*Power cord is only available with a General Purpose motor

Example: H302-FT-AA1 = Double Head Hi-Performance Dia-Vac® pump with 316 ss wetted parts, Teflon/EPDM diaphragm, 115v 60Hz GP motor

E-Series

Capacity

Style

Eccentric

Heads

E=Extreme Performance

25

1

Wetted Materials

Head

Diaphragm

F=316 SS

P=3-Ply Teflon

L=SilcoNert™ 2000 316 SS

Motor

Type

Voltage

Frequency/Phase

A=General Purpose

A=115

1=60 Hz 1 Ph

F=ATEX IIC 1/2 HP

B=230

2=50 Hz 1 Ph

N=Div 1 Gr C,D 1/2 HP

Optional

Options

M=Heated w/ K Thermocouple

Example: E251-FP-AA1 = E-Series Dia-Vac® pump with 316 ss wetted parts, All-Teflon diaphragm, 115v 60Hz GP motor