Elevated M-Series Dia-Vac® Pump Single Head Hazardous Area

The M-Series Dia-Vac® is now available with a variety of hazardous area motors.

The “Mini” Dia-Vac® is the classic workhorse pump for your system.

The capacity to flow 20 LPM in a small, but rugged design has made this a staple in hazardous area CEMS systems worldwide.

Key Specifications

Max Pressure (psig)

6 - 35

psig

Max Vacuum (InHg)

7 - 21

InHg

Max Flow Rate (slpm)

12 - 39

SLPM

ADI’s gas sampling Dia-Vac® Pumpscan pass your gas at the speed of need! Due to an increased interest in reducing the pressure, vacuum, and/or flow on the Dia-Vac® pumps, our engineers designed a modified eccentric design.

This allows you to customize your Dia-Vac® pump to meet your application requirements while at the same time increasing the diaphragm and bearing life. The standard eccentric size is 0.160 on theM-Series Dia-Vac® Pump. Please note that the chart below is not meant to be read as a combination of pressure and vacuum at the same time, only pressure or vacuum.

If you're looking for head connection schematics you can find them on our dedicated page.

Flow Averages

(Please click on individual Model # for actual performance curves)

M-Series Performance — US Units

Model

Max pressure (PSIG)

Ultimate vacuum (inHg gauge reading)

Max flow (SCFM)

Performance PDF

M081

6

7

0.42

Performance curve

M101

17

17

0.49

Performance curve

M121

19

18

0.59

Performance curve

M151

29.1

19.7

0.7

 

M161

35

20.7

0.75

Performance curve

M162 (Parallel)

35

21

1.3

Performance curve

Head Connection Schematics

M-Series Performance — Metric Units

Model

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge reading)

Max flow (SLPM)

Performance PDF

M081

0.41

237

12

Performance curve

M101

1.17

575

14

Performance curve

M121

1.31

609

16.8

Performance curve

M151

2

667

20

Performance curve

M161

2.41

701

21.4

Performance curve

M162 (Parallel)

2.41

711

39

Performance curve

How to Order

Use the options below to identify your preferred pump configuration. Contact Air Dimensions to confirm compatibility and the complete model number.

How to Configure Your Pump

  1. Choose your pump capacity
    Select the eccentric size and number of heads based on your required performance.
  2. Select wetted materials
    Choose head and diaphragm materials suitable for the gas being handled.
  3. Specify motor requirements
    Identify the appropriate motor type, voltage and frequency for your installation.
  4. Review additional options
    Consider any special requirements, such as an elevated head or alternative housing orientation.
  5. Request a quote
    Share your selections with the Air Dimensions team to confirm compatibility, availability and pricing.

Understanding the Ordering Codes

Each section of the ordering guide represents a different pump configuration characteristic, including capacity, materials, motor specifications and optional features.

The available codes help identify the required specifications when discussing your pump configuration with our team.

Please note: Not all combinations of components and options may be available or compatible. Contact Air Dimensions to confirm the correct configuration and complete model number before ordering.

 

Category

Selection

Available codes / descriptions

Capacity

Style

M = M-Series

Capacity

Eccentric size

16, 15, 14, 12, 10, 8

Capacity

Number of heads

1, 2

Wetted materials

Head material

A = Aluminum; B = Teflon/Aluminum; F = 316 stainless steel; G = Teflon-coated 316 stainless steel; H = Hastelloy C; J = Teflon-coated Hastelloy C; L = SilcoNert® 316 stainless steel; T = Solid Teflon; P = Electropolish

Wetted materials

Diaphragm

E = Encapsulated Teflon/EPDM*; N = EPDM; P = All Teflon; T = Teflon/EPDM

Motor

Motor type

C = General Purpose; W = XP Div. 2; Z = ATEX Zone 2 IIC

Motor

Voltage

A = 115 AC; B = 230 AC; X = N/A

Motor

Frequency

0 = N/A; 1 = 60 Hz, single-phase; 2 = 50 Hz, single-phase

Options

Optional features

L = Elevated Head; M = Heated with K Thermocouple; M1 = Heated with RTD; M2 = Heated with 65°C thermostat; M3 = Heated with 100°C thermostat; M4 = Heated with 140°C thermostat; M5 = Heated with 163°C thermostat; M6 = Heated with 200°C thermostat