M-Series Dia-Vac® Heated Head Pump for Hot/Wet CEMS

The M-Series Heated Head Dia-Vac® pump combines the compact M-Series platform with temperature control through the pump head. It is designed for hot/wet gas sampling systems where the sample must remain above its dew point before reaching downstream analytical equipment.

Multiple Single Head performance options, wetted materials and temperature-sensing configurations allow the pump to be matched to the sampling-system requirements.

Key Specifications

Max Pressure (psig)

6 - 35

psig

Max Vacuum (InHg)

7 - 21

InHg

Max Flow Rate (slpm)

12 - 39

SLPM

Hot/wet gas samples must remain above their dew point through the sample path. Cooling inside the pump can lead to condensation that may affect the pump, sample integrity and analyzer performance.

The M-Series Heated Head provides temperature control through the pump while retaining the compact format used in CEMS cabinets, mobile stack-testing systems and enclosed analytical equipment.

Heated Head vs Standard M-Series

Choose the standard M-Series compact gas sampling pump when the required operating point can be achieved without active temperature control through the pump head. 

Choose the Heated Head configuration when the sample must remain above its dew point through the pump as part of a heated gas-sampling system.

Temperature Sensing and Control

The M-Series Heated Head is available with several temperature-sensing and control configurations:

  • K-type thermocouple
  • Fixed thermostat
  • PT100 RTD

The correct option depends on the sample temperature, dew point, system controls and electrical requirements. Thermocouple and RTD configurations require compatible external temperature-control equipment.

Use the M081-M161 Single Head performance data to identify potential models, then confirm the actual operating point with the applicable model curve.

Maximum pressure, vacuum and flow values represent different conditions and should not be interpreted as simultaneous performance.

If the system requires additional flow, compare the M-Series compact Double Head gas sampling pump.

Flow Averages

(Please click on individual Model # for actual performance curves)

M-Series Performance — US Units

Model

Max pressure (PSIG)

Ultimate vacuum (inHg gauge reading)

Max flow (SCFM)

Performance PDF

M081

6

7

0.42

Performance curve

M101

17

17

0.49

Performance curve

M121

19

18

0.59

Performance curve

M151

29.1

19.7

0.7

 

M161

35

20.7

0.75

Performance curve

M162 (Parallel)

35

21

1.3

Performance curve

Head Connection Schematics

M-Series Performance — Metric Units

Model

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge reading)

Max flow (SLPM)

Performance PDF

M081

0.41

237

12

Performance curve

M101

1.17

575

14

Performance curve

M121

1.31

609

16.8

Performance curve

M151

2

667

20

Performance curve

M161

2.41

701

21.4

Performance curve

M162 (Parallel)

2.41

711

39

Performance curve

For hot/wet CEMS in classified areas using an externally heated enclosure, review the M-Series Elevated Head pump for hazardous-area CEMS.

Maintain the heated sample line and pump head above the sample dew point. Mount the pump with the head facing downward and position the pump at the highest practical point in the system to reduce the risk of liquid entering the pump head.

Follow the M-Series Heated operating instructions and the approved gas sample system design using diaphragm pumps for the selected configuration.

Compact Single Head Platform 

The compact M-Series format supports installation in CEMS cabinets and enclosed analytical equipment. 

Configurable Performance 

Select the eccentric size according to the required sample flow, vacuum and outlet-pressure conditions. 

Heated 316 Stainless Steel Head 

The heated pump head uses 316 stainless steel wetted surfaces in the standard published configuration. 

Continuous Operation 

The M-Series platform is designed for continuous gas-sampling applications. 

Configurable Wetted Materials 

Select pump-head and diaphragm materials according to the sample chemistry, temperature, moisture and expected condensate.

Continuous Emissions Monitoring 

Support hot/wet sample transport in compact CEMS where temperature control through the pump is required. 

Mobile Stack Testing 

Integrate the compact Heated Head pump into mobile emissions-testing and analyzer systems. 

Process Gas Analysis 

Transport temperature-controlled gas samples to downstream analytical equipment. 

Stack and Flue Gas Sampling 

Support extractive gas-analysis systems where moisture and sample-path temperature must be managed. 

Environmental Monitoring 

Integrate the pump into analytical systems requiring continuous transport of heated or moisture-containing gas samples. 

How to Select the M-Series Heated Head

1. Define sample temperature and dew point

Provide both if available. 

2. Define required flow and response time

Identify the required transport performance. 

3. Define inlet and outlet conditions

Provide sample-point pressure and analyzer requirements. 

4. Describe the heated sample path

Include tubing length and diameter, line temperature, filters and sample-conditioning components. 

5. Select the Single Head model

Compare M081-M161 using the applicable performance curves. 

6. Confirm gas and materials

Provide composition, moisture and expected condensate. 

7. Select temperature control

Identify K-type thermocouple, fixed thermostat or PT100 RTD as the preferred arrangement, or let Air Dimensions recommend the configuration. 

8. Confirm electrical requirements

Provide voltage and frequency.

How to Order an M-Series Heated Head pump

Ready to configure an M-Series Heated Head pump? Start with the gas and thermal requirements. 

SIMPLE PROCESS LINE

Define the application  →  Request a Quote  →  Confirm the configuration

Include the sample temperature, dew point if known, required flow or response time, inlet and outlet conditions, sampled gas, heated-line information, preferred temperature-sensing option, voltage and frequency. 

Our team will confirm the appropriate Single Head model, eccentric size, wetted materials and temperature-control arrangement. 

NOT SURE WHICH SENSOR OR THERMOSTAT TO SELECT?

Click "Contact Us" button and fill out the form. An Applications Expert can review the gas temperature, dew point and sampling-system requirements before the complete configuration is finalized. 

Understanding the Ordering Codes

Each section of the ordering guide represents a different pump configuration characteristic, including capacity, materials, motor specifications and optional features.

The available codes help identify the required specifications when discussing your pump configuration with our team.

Please note: Not all combinations of components and options may be available or compatible. Contact Air Dimensions to confirm the correct configuration and complete model number before ordering.

 

Category

Selection

Available codes / descriptions

Capacity

Style

M = M-Series

Capacity

Eccentric size

16, 15, 14, 12, 10, 8

Capacity

Number of heads

1, 2

Wetted materials

Head material

A = Aluminum; B = Teflon/Aluminum; F = 316 stainless steel; G = Teflon-coated 316 stainless steel; H = Hastelloy C; J = Teflon-coated Hastelloy C; L = SilcoNert® 316 stainless steel; T = Solid Teflon; P = Electropolish

Wetted materials

Diaphragm

E = Encapsulated Teflon/EPDM*; N = EPDM; P = All Teflon; T = Teflon/EPDM

Motor

Motor type

C = General Purpose; W = XP Div. 2; Z = ATEX Zone 2 IIC

Motor

Voltage

A = 115 AC; B = 230 AC; X = N/A

Motor

Frequency

0 = N/A; 1 = 60 Hz, single-phase; 2 = 50 Hz, single-phase

Options

Optional features

L = Elevated Head; M = Heated with K Thermocouple; M1 = Heated with RTD; M2 = Heated with 65°C thermostat; M3 = Heated with 100°C thermostat; M4 = Heated with 140°C thermostat; M5 = Heated with 163°C thermostat; M6 = Heated with 200°C thermostat

* Encapsulated Teflon/EPDM: Teflon head only (as labeled on the source page). Confirm compatible combinations and final part-number construction with Air Dimensions.

Configure the M-Series for Your Hot/Wet CEMS

Tell us the sample temperature, dew point, required flow, inlet and outlet conditions, gas composition, heated-line details and electrical requirements. Our team can help select a compact Heated Head configuration using Dia-Vac® diaphragm pump technology. 

REACH OUT TO US