The R-Series single head pump is available with multiple motor, diaphragm and pump-head options. Select the configuration based on required performance, sampled gas, installation environment and material compatibility.
Double Diaphragm Option
A double diaphragm option is available for selected configurations. Review the applicable operating and supplemental instructions or contact Air Dimensions to confirm the correct configuration for the application.
How to Select the Right Single Head Gas Sampling Pump
Pump selection should be based on the required operating point of the complete sampling system, rather than maximum vacuum or free-flow performance alone.
1. Determine the required operating vacuum
Account for tubing, filters, valves and other system components that create pressure loss.
2. Determine the required sample flow
Identify the flow required at the actual system operating vacuum.
3. Compare the Single Head models
Use the published R061-R271 performance data to identify potential configurations.
4. Check the individual performance curve
Confirm that the selected model provides the required flow at the required operating vacuum.
5. Select wetted materials and motor configuration
Choose head, diaphragm and valve materials appropriate for the sampled gas, then select the required motor type, voltage and frequency.