Products
Explosion-Proof Pumps
Gas Analyzer Pumps
Pump Selector
Product Finder
Services
Diaphragm Pump Repair Videos
Frequently Asked Questions
Head Connection Schematics
Gas Diaphragm Pump Spare Parts
Contact Us
How To Order
Applications
Mining Gas Sampling
Aquaculture Gas Sampling
Fenceline Monitoring
SCR Monitoring
Knowledge Hub
Dia-Vac® Gas Diaphragm Pump Technology
Combination Curves
Gas Sample System Design Using Diaphragm Pumps
Methods for Diaphragm Pump Selection
Standard Motors
Solution For Safe & Reliable Gas Transfer
Hydrogen-Compatible Pumps
About Us
News
Back to the product list

R-Series Dia-Vac® Single Head Gas Sampling Pump

R-Series single head gas sampling pumps provide configurable vacuum and flow for gas sampling and analysis applications. Multiple R-Series models are available to meet different operating requirements, with performance determined by model and eccentric size. 

Choose from available motor, wetted material and diaphragm options to configure the pump for the sampled gas and installation requirements. 

Key Specifications

Max Pressure (psig)

6.1 - 71

psig

Max Vacuum (InHg)

8.4 - 25.2

InHg

Max Flow Rate (slpm)

9.4 - 30.2

SLPM

R-Series single head performance varies by model and eccentric size. Use the published performance data to identify models that match the required vacuum and sample flow. 

  • Maximum pressure: 6.1-71 psig
  • Ultimate vacuum: 8.4-25.2 inHg
  • Maximum flow: 9.4-30.2 SLPM

Maximum pressure, vacuum and flow values represent different operating conditions and should not be interpreted as simultaneous performance. Refer to the individual model curve for pump selection.

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Single Head — US Units 

Model #

PSIG (Max Pressure)

InHg Gauge (Ultimate Vacuum)

SCFM (Max Flow)

Datasheet

R061

6.1

8.4

0.33

Download PDF

R081

9.6

11.8

0.47

Download PDF

R101

11

13.9

0.47

Download PDF

R121

17

16

0.57

Download PDF

R151

22

18.8

0.66

Download PDF

R181

34.2

21.4

0.77

Download PDF

R201

45.1

22.6

0.86

Download PDF

R221

55

24

0.95

Download PDF

R251

71

24.6

0.98

Download PDF

R271

71

25.2

1.06

Download PDF

 

R-Series Single Head — Metric Units 

Model #

Bar Gauge (Max Pressure)

mbar Gauge (Ultimate Vacuum)

SLPM (Max Flow)

Datasheet

R061

0.42

284

9.4

Download PDF

R081

0.66

399

13.2

Download PDF

R101

0.75

470

13.4

Download PDF

R121

1.17

541

16.4

Download PDF

R151

1.52

636

18.9

Download PDF

R181

2.36

725

21.8

Download PDF

R201

3.11

765

24.5

Download PDF

R221

3.8

813

27

Download PDF

R251

4.9

833

27.8

Download PDF

R271

4.9

853

30.2

Download PDF

 

A single head diaphragm pump uses one pump head to draw and transport gas through a sampling system. Within the R-Series, different eccentric sizes provide different combinations of vacuum, pressure and sample flow. 

Selecting the appropriate model depends on the required flow at the system’s actual operating vacuum rather than on maximum performance values alone. 

The published R-Series Single Head range includes models from R061 through R271. The current page identifies 0.222 as the standard eccentric size for the R-Series Dia-Vac® pump.

A single-head configuration uses one pump head, while double-head configurations provide additional optionsfor increasing sample flow or vacuum capability. quad-head configurations.

A single head pump may be the appropriate choice when the required operating point falls within the performance range of one of the available single-head models. If the system requires performance beyond that range, compare the available double-head or 

The correct configuration should be selected using the required flow at the actual operating vacuum, confirmed against the applicable performance curve.

 

Find dimensional drawings and parts lists for each R-Series Single Head configuration. Shared instructions and the product brochure are listed below.

Configuration

Dimensional Drawing

Parts List

General Purpose AC Motor

PDF

PDF 

TEFC Motor

PDF

PDF 

Double Diaphragm

PDF

PDF 

Solid Teflon Head

PDF

PDF

Operating Instructions 

Choose a single head configuration when the required vacuum and sample flow can be achieved by one of the available R-Series single-head models. 

The published range provides multiple operating options from R061 through R271, with different vacuum, pressure and flow characteristics across the available eccentric sizes. For final selection, use the individual performance curve rather than relying only on maximum values in the comparison table. 

If the application requires increased vacuum beyond the normal Single Head range, compare the available R-Series High Vacuum Pump. 

R-Series single head pumps support gas sampling and analysis systems requiring configurable vacuum and sample flow performance. 

Continuous Emissions Monitoring 

Transport gas samples through sampling lines, filters and sample conditioning components to analytical equipment. 

Process Gas Analysis 

Move gas samples from a process to downstream analysis or monitoring equipment. 

Environmental Monitoring 

Support gas sample transport in environmental and air monitoring systems. 

Analytical Gas Sampling 

Provide configurable vacuum and flow for analytical sampling equipment. 

The R-Series single head pump is available with multiple motor, diaphragm and pump-head options. Select the configuration based on required performance, sampled gas, installation environment and material compatibility.

Double Diaphragm Option

A double diaphragm option is available for selected configurations. Review the applicable operating and supplemental instructions or contact Air Dimensions to confirm the correct configuration for the application.

How to Select the Right Single Head Gas Sampling Pump

Pump selection should be based on the required operating point of the complete sampling system, rather than maximum vacuum or free-flow performance alone. 

1. Determine the required operating vacuum 

Account for tubing, filters, valves and other system components that create pressure loss. 

2. Determine the required sample flow 

Identify the flow required at the actual system operating vacuum. 

3. Compare the Single Head models 

Use the published R061-R271 performance data to identify potential configurations. 

4. Check the individual performance curve 

Confirm that the selected model provides the required flow at the required operating vacuum. 

5. Select wetted materials and motor configuration 

Choose head, diaphragm and valve materials appropriate for the sampled gas, then select the required motor type, voltage and frequency. 

Ready to order an R-Series single head pump? Getting started is simple. 

SIMPLE PROCESS LINE 

Select your pump  →  Request a Quote  →  Talk to our Sales Team 

Review the Single Head performance data, then click Request a Quote and tell us which model or configuration you’re interested in. Our Sales Team will contact you to confirm the specifications, discuss your application and help finalize your order. 

ALTERNATIVE PATH 

Not sure which model you need? You don’t have to select the exact model first. Click Ask a Question to connect with an expert. We’ll help you identify the R-Series configuration that best fits your required vacuum, sample flow, sampled gas and installation conditions.

elevated-r-series-dia-vac-pump-single-head-hazardous-area-air-dimensions-inc.png
Example: RVA2-FT-AA1 = High Vacuum Dia-Vac® pump, 316 ss heads, Teflon/EPDM diaphragms, 115v 60Hz motor.

REACH OUT TO US