J-Series Dia-Vac® Pump IECEx/ATEX Flameproof Zone 1 IIC T4 Ambient Temp 50 C IP66

Introducing the all new ATEX/IECEx Zone 1 rated J-Series Dia-Vac® pump.

The smallest Dia-Vac® pump available with a hazardous area motor; this pump provides a flow rate up to 14 SLPM, maximum vacuum up to 23 InHg, and a maximum pressure of 29 psig. An ideal choice for hazardous area rated CEM systems and OEM customers.

*Note that pump motor is also approved for Korea (KOSHA) and India (PESO).

ADI’s gas sampling Dia-Vac® Pumps can pass your gas at the speed of need! Due to an increased interest in reducing the pressure, vacuum, and/or flow on the Dia-Vac® pumps, our engineers designed a modified eccentric design. This allows you to customize your Dia-Vac® pump to meet your application requirements while at the same time increasing the diaphragm and bearing life. The standard eccentric size is 0.160 on the J-Series Dia-Vac® Pump.

Please note that the chart below is not meant to be read as a combination of pressure and vacuum at the same time, only pressure or vacuum.

J-Series Dia-Vac®

Flow Averages

(Please click on individual Model # for actual performance curves)

 

Model #

PSIG (Max Pressure)

Bar Gauge (Max Pressure)

InHg Gauge (Ultimate Vacuum)

Mbar Gauge (Ultimate Vacuum)

SCFM (Max Flow)

SLPM (Max Flow)

 

J081

10.5

0.7

16.4

555

0.24

6.7

J081.pdf

J081-Metric

 

 

 

 

 

 

 

J081_Metric.pdf

J101

14.5

1

19.2

650

0.31

8.8

 

J101_Metric.pdf

J101-Metric

 

 

 

 

 

 

 

J101_Metric.pdf

J121

20.9

1.44

21

711

0.37

10.6

 

J121.pdf

J121-Metric

 

 

 

 

 

 

 

J121_Metric.pdf

J141

25

1.72

22

745

0.44

12.5

 

J141.pdf

J141-Metric

 

 

 

 

 

 

 

J141_Metric.pdf

J161

31.1

2.14

24.4

826

0.49

14

 

J161.pdf

J161-Metric

 

 

 

 

 

 

 

J161_Metric.pdf

Head Connection Schematics

CAPACITY

WETTED MATERIALS

MOTOR

OPTIONS

STYLE

ECC.

HEADS

HEAD

DIAPHRAGM

TYPE

VOLTS

Hz

OPTIONS

J=J-Series

16

1

A=Alum

T= Teflon/EPDM

A = General Purpose

A=115 AC

0= N/A

M˚=Heated Head w/K T-couple

14*

B=Tef/Alum

P=All Teflon

G = XP/ATEX/IIC

B=230 AC

1=60 1Ph

L=Elevated Head

F=316ss

P = BLDC (var speed)

H=12 DC

2=50 1 Ph

T = BLDC

J=24 DC

*.140 Ecc required for Elevated and Heated Head option.