Products
Explosion-Proof Pumps
Gas Analyzer Pumps
Pump Selector
Product Finder
Services
Diaphragm Pump Repair Videos
Frequently Asked Questions
Head Connection Schematics
Gas Diaphragm Pump Spare Parts
Contact Us
How To Order
Applications
Mining Gas Sampling
Aquaculture Gas Sampling
Fenceline Monitoring
SCR Monitoring
Knowledge Hub
Dia-Vac® Gas Diaphragm Pump Technology
Combination Curves
Gas Sample System Design Using Diaphragm Pumps
Methods for Diaphragm Pump Selection
Standard Motors
Solution For Safe & Reliable Gas Transfer
Hydrogen-Compatible Pumps
About Us
News
Back to the product list

R-Series Heated Head Dia-Vac® Gas Sampling Pump

The R-Series Heated Head Dia-Vac® pump is designed for hot/wet gas sampling systems where the gas sample must remain above its dew point through the pump. Maintaining the required sample temperature helps reduce the risk of condensation before the gas reaches downstream analytical equipment. 

Configure the pump with the appropriate temperature-sensing method, wetted materials, motor and R-Series performance option for the sampling system requirements.

Key Specifications

Max Pressure (psig)

6.1 - 71

psig

Max Vacuum (InHg)

8.4 - 25.2

InHg

Max Flow Rate (slpm)

9.4 - 30.2

SLPM

In hot/wet gas sampling systems, the sample must remain above its dew point from the probe through the sample line, pump and downstream analytical equipment. If the gas cools below its dew point, condensation may affect the pump, sample path and analyzer performance. 

A heated pump head maintains the required temperature through the pump as part of a temperature-controlled gas sampling system.

Choose the Right Thermal Configuration 

Heated Head 

Use a Heated Head configuration when the gas sample must remain above its dew point through the pump in a standard hot/wet sampling application. Current product guidance identifies a typical application range of approximately 50-120°C. 

Elevated Head 

For higher-temperature applications, particularly where the installation environment or hazardous-area requirements do not allow the motor area to be heated, an Elevated Head configuration may be required. Current product guidance identifies a typical range of approximately 120-180°C. 

Extended or Steam-Traced Head 

For very wet or high-temperature sampling systems approaching 200°C, consult Air Dimensions about an Extended or steam-traced head configuration. 

Heated Head pump performance depends on the selected R-Series model, eccentric size and number of heads. Use the published performance tables to identify potential models, then confirm the required operating point using the applicable model curve. 

Maximum pressure, vacuum and flow values represent different operating conditions and should not be interpreted as simultaneous performance. Published performance data is provided for model comparison; actual performance depends on the complete sampling system and operating conditions. 

If you're looking for head connection schematics you can find them on our dedicated page.

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Single Head — US Units 

Model #

PSIG (Max Pressure)

InHg Gauge (Ultimate Vacuum)

SCFM (Max Flow)

Datasheet

R061

6.1

8.4

0.33

Download PDF

R081

9.6

11.8

0.47

Download PDF

R101

11

13.9

0.47

Download PDF

R121

17

16

0.57

Download PDF

R151

22

18.8

0.66

Download PDF

R181

34.2

21.4

0.77

Download PDF

R201

45.1

22.6

0.86

Download PDF

R221

55

24

0.95

Download PDF

R251

71

24.6

0.98

Download PDF

R271

71

25.2

1.06

Download PDF

 

R-Series Single Head — Metric Units 

Model #

Bar Gauge (Max Pressure)

mbar Gauge (Ultimate Vacuum)

SLPM (Max Flow)

Datasheet

R061

0.42

284

9.4

Download PDF

R081

0.66

399

13.2

Download PDF

R101

0.75

470

13.4

Download PDF

R121

1.17

541

16.4

Download PDF

R151

1.52

636

18.9

Download PDF

R181

2.36

725

21.8

Download PDF

R201

3.11

765

24.5

Download PDF

R221

3.8

813

27

Download PDF

R251

4.9

833

27.8

Download PDF

R271

4.9

853

30.2

Download PDF

 

R-Series Double Head Dia-Vac®

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Double Head — US Units 

Model #

Head connection

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

R202

Parallel

46.5

23.3

1.71

60 Hz PDF | 50 Hz PDF

R202

Series

75.0

28.3

1.01

60 Hz PDF | 50 Hz PDF

R222

Parallel

55.0

24.0

1.80

60 Hz PDF | 50 Hz PDF

R222

Series

75.0

28.6

0.98

60 Hz PDF | 50 Hz PDF

R252

Parallel

69.8

25.1

2.06

60 Hz PDF | 50 Hz PDF

R252

Series

75.0

28.9

1.12

60 Hz PDF | 50 Hz PDF

R272

Parallel

75.0

25.3

2.37

60 Hz PDF | 50 Hz PDF

R272

Series

75.0

29.2

1.24

60 Hz PDF | 50 Hz PDF

 

R-Series Double Head — Metric Units

Model #

Head connection

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge*)

Max flow (SLPM)

Performance curves

R202

Parallel

3.20

789

48.5

60 Hz PDF | 50 Hz PDF

R202

Series

5.17

958

28.7

60 Hz PDF | 50 Hz PDF

R222

Parallel

3.79

812

51.1

60 Hz PDF | 50 Hz PDF

R222

Series

5.17

968

27.8

60 Hz PDF | 50 Hz PDF

R252

Parallel

4.81

850

58.4

60 Hz PDF | 50 Hz PDF

R252

Series

5.17

978

31.8

60 Hz PDF | 50 Hz PDF

R272

Parallel

5.17

856

67

60 Hz PDF | 50 Hz PDF

R272

Series

5.17

988

35

60 Hz PDF | 50 Hz PDF

 

R-Series Quad Head Dia-Vac®

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Quad Head — US Units

Model #

Head connection

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

R224

Parallel

70

24.8

3.53

60 Hz PDF | 50 Hz PDF

R224

Series

75

29.4

0.98

60 Hz PDF | 50 Hz PDF

R224

Series/Parallel

75

28.6

1.89

60 Hz PDF | 50 Hz PDF

R254

Parallel

75.0

24.9

3.8

60 Hz PDF | 50 Hz PDF

R254

Series

75.0

29.4

1.1

60 Hz PDF | 50 Hz PDF

R254

Series/Parallel

75.0

29.1

2.0

60 Hz PDF | 50 Hz PDF

 

R-Series Quad Head — Metric Units 

Model #

Head connection

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge*)

Max flow (SLPM)

Performance curves

R224

Parallel

4.80

839

100

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series

5.17

995

27.8

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series/Parallel

5.17

968

53.7

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Parallel

5.17

839

108

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series

5.17

995

31.4

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series/Parallel

5.17

985

57.1

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

 

R-Series thermal options include K-type thermocouple, PT100 RTD, fixed-temperature thermostat and steam-heated configurations. Select the temperature-control method based on the required sample temperature and system controls. 

  • K-type thermocouple
  • PT100 RTD
  • Fixed-temperature thermostat options
  • Steam-heated option

Thermocouple and RTD configurations require compatible external temperature-control equipment. Confirm the complete control arrangement before ordering. 

Correct installation is important in hot/wet gas sampling systems. Current Air Dimensions guidance recommends mounting the pump with the head facing downward and positioning the pump at the highest practical point in the system to reduce the risk of liquid pooling. 

The sample line and pump head should be maintained above the sample dew point. Follow the operating instructions and approved system design for the selected pump configuration.

Hot/Wet Gas Sampling 

Maintain the gas sample above its dew point through the pump as part of a temperature-controlled sampling system. 

Continuous Emissions Monitoring 

Support heated sample transport in CEMS where temperature must be controlled before the sample reaches downstream analytical equipment. 

Process Gas Analysis 

Transport heated process gas samples through the pump to downstream analysis or monitoring equipment. 

Extractive Gas Analysis 

Support extractive sampling systems where condensation must be considered in the design of the complete sample path. 

The Heated Head configuration adds thermal management for applications where the sample must remain above its dew point through the pump. A standard R-Series configuration may be sufficient when temperature control through the pump is not required. 

Pump selection should account for both vacuum, pressure and sample flow requirements and the thermal requirements of the complete sampling system. 

If the application requires increased vacuum or higher-flow configurations, compare the relevant R-Series performance data before selecting the thermal option. 

1. Define the sample temperature and dew point 

Determine the required temperature through the pump and confirm the sample dew point. If the dew point is unknown, consult Applications Engineering before selecting the thermal configuration. 

2. Select the thermal configuration 

Choose Heated, Elevated, Extended or steam-traced head based on sample temperature, moisture conditions and installation classification. 

3. Determine vacuum and flow requirements 

Account for sample-point pressure, analyzer requirements, tubing length and diameter, filters, conditioning components and the final discharge point. 

4. Select the temperature-control method 

Choose the required thermocouple, RTD, fixed thermostat or steam-heated configuration and confirm compatible control equipment. 

5. Select wetted materials 

Choose materials based on the sampled gas and corrosion risk. Heated or wet service alone does not establish material compatibility. 

6. Confirm installation and electrical requirements 

Select Materials for the Sampled Gas

Confirm motor type, voltage, frequency, ambient temperature and safe-area or hazardous-area classification. 

Select Materials for the Sampled GasConfirm the compatibility of the pump-head, diaphragm, valve and sealing materials with the sampled gas and expected moisture or condensate. Available R-Series wetted-material options include 316 stainless steel, PTFE-based options, Hastelloy C and treated surfaces for specific gas-analysis requirements. 

How to Order Your R-Series Dia-Vac® Pump

Ready to order an R-Series pump? Getting started is simple.

SIMPLE PROCESS LINE

Select your pump → Request a Quote → Talk to our Sales Team

Choose the model or configuration that best matches your requirements, then click Request a Quote and tell us which pump you're interested in. Our Sales Team will contact you to confirm the specifications, discuss your application and help finalize your order.

ALTERNATIVE PATH

Not sure which pump you need? You don't have to choose a model first. Click Ask a Question to connect with one of our experts. We'll help you identify the R-Series configuration that best fits your application.

 

R-Series Dia-Vac® pumps are available with a variety of head configurations, wetted materials, motor specifications, and optional features to meet your application requirements.

Use the ordering guide below to explore the available configurations. When requesting a quote, provide your preferred specifications or describe your application requirements so our team can help identify a suitable pump configuration.

How to Configure Your Pump

  1. Choose your pump capacity

    Select the eccentric size and number of heads based on your required performance.

  2. Select wetted materials

    Choose head and diaphragm materials suitable for the gas being handled.

  3. Specify motor requirements

    Identify the appropriate motor type, voltage and frequency for your installation.

  4. Review additional options

    Consider any special requirements, such as an elevated head or alternative housing orientation.

  5. Request a quote

    Share your selections with the Air Dimensions team to confirm compatibility, availability and pricing.

Understanding the Ordering Codes

Each section of the ordering guide represents a different pump configuration characteristic, including capacity, materials, motor specifications and optional features.

The available codes help identify the required specifications when discussing your pump configuration with our team.

Please note: Not all combinations of components and options may be available or compatible. Contact Air Dimensions to confirm the correct configuration and complete model number before ordering.

 

Category

Selection

Available codes and descriptions

Capacity

Pump style

B — Standard

Capacity

Eccentric size

27; 25; 22; 20; 18; 15; 12; 10; 08; 06

Capacity

Number of heads

1; 2; 4; 8

Wetted materials

Head material

A — Alum; B — Tef/Alum; F — 316ss; G — 316ss (TefCo); H — Hastelloy C; J — Hast. C (TefCo); L — Silconert®316ss; P — Electro Polish; T — Solid Teflon

Wetted materials

Diaphragm

E — Encap Tef/EPDM*; N — EPDM; P — All Teflon; T — Tef/EPDM; V — Viton

Motor

Motor type

D — Air; N — XP(Gr CD) 1/2 HP; Q — ATEX/IECEx (IIC) .55kW; R — XP Gr.B,C,D (UL) 1/6 HP; V — XP (C,D) 1HP; Y — ATEX/IECEx (IIC) .37kW

Motor

Voltage

A — 115; B — 230; D — 220/380; E — 230/460; X — N/A

Motor

Frequency

0 — N/A; 1 — 60 1Ph; 2 — 50 1Ph; 3 — 60 3Ph; 4 — 50 3Ph

Options

Additional options

A — 416ss Valve Discs; D — Double Diaphragm; E2 — Extended Head; L — Elevated Head; P — Epoxy coatfor offshore; M8 — Heated Steam (XP); X — Rotate Housing 90° CW; Y — Rotate Housing 90° CCW; Z — Rotate Housing 180°

 

REACH OUT TO US