Products
Explosion-Proof Pumps
Gas Analyzer Pumps
Pump Selector
Product Finder
Services
Diaphragm Pump Repair Videos
Frequently Asked Questions
Head Connection Schematics
Gas Diaphragm Pump Spare Parts
Contact Us
How To Order
Applications
Mining Gas Sampling
Aquaculture Gas Sampling
Fenceline Monitoring
SCR Monitoring
Knowledge Hub
Dia-Vac® Gas Diaphragm Pump Technology
Combination Curves
Gas Sample System Design Using Diaphragm Pumps
Methods for Diaphragm Pump Selection
Standard Motors
Solution For Safe & Reliable Gas Transfer
Hydrogen-Compatible Pumps
About Us
News
Back to the product list

R-Series Dia-Vac® Quad Head Gas Sampling Pump

R-Series quad head gas sampling pumps provide configurable vacuum and flow performance for demanding gas sampling and analysis systems. The four-head design can be configured to prioritize higher sample flow or increased vacuum, depending on the model and head connection. 

Choose from multiple motor, wetted material and diaphragm options to configure the pump for the application and installation requirements.

Key Specifications

Max Pressure (psig)

70 - 75

psig

Max Vacuum (InHg)

24.8 - 29.4

InHg

Max Flow Rate (slpm)

27.8 - 108

SLPM

Air Dimensions R-Series quad head performance varies by model and head connection. Published R224 and R254 configurations provide different combinations of vacuum and flow, allowing pump performance to be matched to the requirements of the sampling system.

  • Maximum pressure: 70-75 psig
  • Ultimate vacuum: 24.8-29.4 inHg
  • Maximum flow: 27.8-108 SLPM

Maximum pressure, vacuum and flow values represent different operating conditions and should not be interpreted as simultaneous performance. Refer to the individual performance curve for model-specific selection.

Compare R-Series configurations using the performance data below. Vacuum and flow vary by model, head connection and operating frequency.

For quad head pump selection, review the R224 and R254 performance data and open the applicable model curve. Values separated by a slash represent alternative head configurations and should not be interpreted as simultaneous performance.

R-Series Quad Head Dia-Vac®

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Quad Head — US Units

Model #

Head connection

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

R224

Parallel

70

24.8

3.53

60 Hz PDF | 50 Hz PDF

R224

Series

75

29.4

0.98

60 Hz PDF | 50 Hz PDF

R224

Series/Parallel

75

28.6

1.89

60 Hz PDF | 50 Hz PDF

R254

Parallel

75.0

24.9

3.8

60 Hz PDF | 50 Hz PDF

R254

Series

75.0

29.4

1.1

60 Hz PDF | 50 Hz PDF

R254

Series/Parallel

75.0

29.1

2.0

60 Hz PDF | 50 Hz PDF

 

R-Series Quad Head — Metric Units 

Model #

Head connection

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge*)

Max flow (SLPM)

Performance curves

R224

Parallel

4.80

839

100

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series

5.17

995

27.8

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series/Parallel

5.17

968

53.7

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Parallel

5.17

839

108

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series

5.17

995

31.4

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series/Parallel

5.17

985

57.1

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

 

Find dimensional drawings, parts lists and operating instructions for each R-Series Quad Head configuration.

Configuration

Dimensional Drawing

Parts List

Operating Instructions 

General Purpose AC Motor

PDF

PDF

Standard manual

High Speed Motor

PDF

PDF

Standard manual 

TEFC Motor

PDF

PDF

Standard manual 

Double Diaphragm

PDF

PDF

Standard manual 

Solid Teflon Head

PDF

PDF

Teflon-head manual

Additional Resources

A quad head pump uses four pump heads driven by a common motor. Different head connections provide different combinations of vacuum and flow, allowing the pump to be configured around the operating requirements of the sampling system.

The published R-Series quad head data includes alternative parallel and series performance values. Higher-flow configurations provide up to 108 SLPM, while alternative configurations provide increased vacuum capability up to 29.4 inHg.

View Head Connection Schematics for the available connection arrangements.

The main difference between double-head configurations and quad-head configurations is the available range of flow and vacuum performance. Four pump heads provide additional configuration flexibility for systems requiring higher sample flow or increased vacuum capability. 

A quad head pump is not automatically the better choice for every application. Select the pump based on the required flow at the actual operating vacuum and confirm the operating point using the applicable performance curve. 

Higher Sample Flow 

Published R224 and R254 configurations provide maximum flow values up to 100 and 108 SLPM respectively. 

Increased Vacuum Capability 

Alternative head configurations provide increased vacuum capability up to 29.4 inHg for the published R224 and R254 models. 

Configurable Performance 

Multiple head connections allow different combinations of sample flow and vacuum to match the sampling system requirements. 

R-Series quad head pumps are designed for gas sampling and analysis systems that require configurable vacuum and higher sample flow performance. 

Continuous Emissions Monitoring 

Support sample transport through sampling lines, filters and sample conditioning equipment. 

Process Gas Analysis 

Move gas samples from the process to downstream analytical or monitoring equipment. 

Environmental Monitoring 

Support gas sampling systems where tubing and system components create additional resistance to flow. 

High-Flow Analytical Gas Sampling 

Provide higher flow capability for gas analysis systems with demanding sample transport requirements. 

The R-Series quad head pump is available with multiple motor, diaphragm and pump-head options. Select the configuration based on required performance, sampled gas, installation environment and material compatibility. 

Double Diaphragm Option

A double diaphragm option is available for selected configurations. Review the applicable operating and supplemental instructions or contact Air Dimensions to confirm the appropriate configuration for the application. 

Ready to order an R-Series quad head pump? Getting started is simple. 

SIMPLE PROCESS LINE 

Select your pump  →  Request a Quote  →  Talk to our Sales Team 

Review the R224 and R254 performance data, then click Request a Quote and tell us which model or configuration you're interested in. Our Sales Team will contact you to confirm the specifications, discuss your application and help finalize your order. 

ALTERNATIVE PATH 

Not sure which configuration you need? You don't have to select the exact model or head arrangement first. Click Ask a Question to connect with an expert. We'll help you identify the R-Series configuration that best fits your required vacuum, sample flow, sampled gas and installation conditions.

elevated-r-series-dia-vac-pump-single-head-hazardous-area-air-dimensions-inc.png

Example: RVA2-FT-AA1 = High Vacuum Dia-Vac® pump, 316 ss heads, Teflon/EPDM diaphragms, 115v 60Hz motor.

REACH OUT TO US