Products
Explosion-Proof Pumps
Gas Analyzer Pumps
Pump Selector
Product Finder
Services
Diaphragm Pump Repair Videos
Frequently Asked Questions
Head Connection Schematics
Gas Diaphragm Pump Spare Parts
Contact Us
How To Order
Applications
Mining Gas Sampling
Aquaculture Gas Sampling
Fenceline Monitoring
SCR Monitoring
Knowledge Hub
Dia-Vac® Gas Diaphragm Pump Technology
Combination Curves
Gas Sample System Design Using Diaphragm Pumps
Methods for Diaphragm Pump Selection
Standard Motors
Solution For Safe & Reliable Gas Transfer
Hydrogen-Compatible Pumps
About Us
News
Back to the product list

R-Series High Vacuum Dia-Vac® Pump (Hazardous Area)

The R-Series High-Vacuum Dia-Vac® pump is an adaptation of our versatile R-Series Dia-Vac® pump, using valves specifically designed for vacuum applications. This pump is highly customizable and can be modified to work with almost any application.

With an absolute vacuum of -29.8 in Hg, this pump can handle all of your vacuum needs.

Key Specifications

Max Pressure (psig)

6.1 - 71

psig

Max Vacuum (InHg)

8.4 - 25.2

InHg

Max Flow Rate (slpm)

9.4 - 30.2

SLPM

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Single Head — US Units 

Model #

PSIG (Max Pressure)

InHg Gauge (Ultimate Vacuum)

SCFM (Max Flow)

Datasheet

R061

6.1

8.4

0.33

Download PDF

R081

9.6

11.8

0.47

Download PDF

R101

11

13.9

0.47

Download PDF

R121

17

16

0.57

Download PDF

R151

22

18.8

0.66

Download PDF

R181

34.2

21.4

0.77

Download PDF

R201

45.1

22.6

0.86

Download PDF

R221

55

24

0.95

Download PDF

R251

71

24.6

0.98

Download PDF

R271

71

25.2

1.06

Download PDF

 

R-Series Single Head — Metric Units 

Model #

Bar Gauge (Max Pressure)

mbar Gauge (Ultimate Vacuum)

SLPM (Max Flow)

Datasheet

R061

0.42

284

9.4

Download PDF

R081

0.66

399

13.2

Download PDF

R101

0.75

470

13.4

Download PDF

R121

1.17

541

16.4

Download PDF

R151

1.52

636

18.9

Download PDF

R181

2.36

725

21.8

Download PDF

R201

3.11

765

24.5

Download PDF

R221

3.8

813

27

Download PDF

R251

4.9

833

27.8

Download PDF

R271

4.9

853

30.2

Download PDF

 

R-Series Double Head Dia-Vac®

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Double Head — US Units 

Model #

Head connection

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

R202

Parallel

46.5

23.3

1.71

60 Hz PDF | 50 Hz PDF

R202

Series

75.0

28.3

1.01

60 Hz PDF | 50 Hz PDF

R222

Parallel

55.0

24.0

1.80

60 Hz PDF | 50 Hz PDF

R222

Series

75.0

28.6

0.98

60 Hz PDF | 50 Hz PDF

R252

Parallel

69.8

25.1

2.06

60 Hz PDF | 50 Hz PDF

R252

Series

75.0

28.9

1.12

60 Hz PDF | 50 Hz PDF

R272

Parallel

75.0

25.3

2.37

60 Hz PDF | 50 Hz PDF

R272

Series

75.0

29.2

1.24

60 Hz PDF | 50 Hz PDF

 

R-Series Double Head — Metric Units

Model #

Head connection

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge*)

Max flow (SLPM)

Performance curves

R202

Parallel

3.20

789

48.5

60 Hz PDF | 50 Hz PDF

R202

Series

5.17

958

28.7

60 Hz PDF | 50 Hz PDF

R222

Parallel

3.79

812

51.1

60 Hz PDF | 50 Hz PDF

R222

Series

5.17

968

27.8

60 Hz PDF | 50 Hz PDF

R252

Parallel

4.81

850

58.4

60 Hz PDF | 50 Hz PDF

R252

Series

5.17

978

31.8

60 Hz PDF | 50 Hz PDF

R272

Parallel

5.17

856

67

60 Hz PDF | 50 Hz PDF

R272

Series

5.17

988

35

60 Hz PDF | 50 Hz PDF

 

R-Series Quad Head Dia-Vac®

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Quad Head — US Units

Model #

Head connection

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

R224

Parallel

70

24.8

3.53

60 Hz PDF | 50 Hz PDF

R224

Series

75

29.4

0.98

60 Hz PDF | 50 Hz PDF

R224

Series/Parallel

75

28.6

1.89

60 Hz PDF | 50 Hz PDF

R254

Parallel

75.0

24.9

3.8

60 Hz PDF | 50 Hz PDF

R254

Series

75.0

29.4

1.1

60 Hz PDF | 50 Hz PDF

R254

Series/Parallel

75.0

29.1

2.0

60 Hz PDF | 50 Hz PDF

 

R-Series Quad Head — Metric Units 

Model #

Head connection

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge*)

Max flow (SLPM)

Performance curves

R224

Parallel

4.80

839

100

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series

5.17

995

27.8

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series/Parallel

5.17

968

53.7

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Parallel

5.17

839

108

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series

5.17

995

31.4

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series/Parallel

5.17

985

57.1

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

 

Use the codes below to identify the available R-Series configuration choices. Contact Air Dimensions to confirm a complete model number, availability, and option compatibility before ordering.

Category

Selection

Available codes and options

Capacity

Pump style

B = Standard 

Capacity

Eccentric size

27; 25; 22; 20; 18; 15; 12; 10; 08; 06 

Capacity

Number of heads

1; 2; 4; 8 

Wetted materials

Head material

A = Alum; B = Tef/Alum; F = 316ss; G = 316ss (TefCo); H = Hastelloy C; J = Hast. C (TefCo); L = Silconert®316ss; P = Electro Polish; T = Solid Teflon

Wetted materials

Diaphragm

E = Encap Tef/EPDM*; N = EPDM; P = All Teflon; T = Tef/EPDM; V = Viton 

Motor

Motor type

D = Air; N = XP(Gr CD) 1/2 HP; Q = ATEX/IECEx (IIC) .55kW; R = XP Gr.B,C,D (UL) 1/6 HP; V = XP (C,D) 1HP; Y = ATEX/IECEx (IIC) .37kW

Motor

Voltage

A = 115; B = 230; D = 220/380; E = 230/460; X = N/A

Motor

Frequency

0 = N/A; 1 = 60 1Ph; 2 = 50 1Ph; 3 = 60 3Ph; 4 = 50 3Ph

Options

Additional options

A = 416ss Valve Discs; D = Double Diaphragm; E2 = Extended Head; L = Elevated Head; P = Epoxy coatfor offshore; M8 = Heated Steam (XP); X = Rotate Housing 90° CW; Y = Rotate Housing 90° CCW; Z = Rotate Housing 180°

Codes and descriptions are reproduced from the current product page. The asterisk after “Encap Tef/EPDM*” is present on the source page, but no corresponding explanation appears in the ordering section. Confirm the meaning of that footnote and compatibility of options with the technical team.