R-Series High Vacuum Gas Sampling Pumps

R-Series high vacuum gas sampling pumps provide configurable vacuum and flow performance for demanding gas sampling and analysis applications. Available in single-, double- and quad-head configurations, the R-Series can be configured to balance vacuum performance and sample flow for specific system requirements.

Choose from multiple pump configurations, wetted materials, diaphragm options and motor types to match your gas sampling application. 

This pump is highly customizable and can be modified to work with almost any application.

Key Specifications

Max Pressure (psig)

6.1 - 75

psig

Max Vacuum (InHg)

8.4 - 29.4

InHg

Max Flow Rate (slpm)

9.4 - 35

SLPM
R-Series performance varies by model, eccentric size and head configuration. Use the tables below to compare available configurations and select the required balance of vacuum and flow.

Single-Head Pumps

Flow: approximately 9.4-30.2 SLPM

Vacuum: approximately 8.4-25.2 inHg

 

Double- and Quad-Head Pumps

Higher-vacuum and higher-flow configurations are available by connecting multiple pump heads in series or parallel. Refer to the performance tables below for model-specific values.

Performance varies by model and operating conditions.

 

If you're looking for head connection schematics you can find them on our dedicated page.

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Single Head — US Units 

Model #

PSIG (Max Pressure)

InHg Gauge (Ultimate Vacuum)

SCFM (Max Flow)

Datasheet

R061

6.1

8.4

0.33

Download PDF

R081

9.6

11.8

0.47

Download PDF

R101

11

13.9

0.47

Download PDF

R121

17

16

0.57

Download PDF

R151

22

18.8

0.66

Download PDF

R181

34.2

21.4

0.77

Download PDF

R201

45.1

22.6

0.86

Download PDF

R221

55

24

0.95

Download PDF

R251

71

24.6

0.98

Download PDF

R271

71

25.2

1.06

Download PDF

 

R-Series Single Head — Metric Units 

Model #

Bar Gauge (Max Pressure)

mbar Gauge (Ultimate Vacuum)

SLPM (Max Flow)

Datasheet

R061

0.42

284

9.4

Download PDF

R081

0.66

399

13.2

Download PDF

R101

0.75

470

13.4

Download PDF

R121

1.17

541

16.4

Download PDF

R151

1.52

636

18.9

Download PDF

R181

2.36

725

21.8

Download PDF

R201

3.11

765

24.5

Download PDF

R221

3.8

813

27

Download PDF

R251

4.9

833

27.8

Download PDF

R271

4.9

853

30.2

Download PDF

 

R-Series Double Head Dia-Vac®

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Double Head — US Units 

Model #

Head connection

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

R202

Parallel

46.5

23.3

1.71

60 Hz PDF | 50 Hz PDF

R202

Series

75.0

28.3

1.01

60 Hz PDF | 50 Hz PDF

R222

Parallel

55.0

24.0

1.80

60 Hz PDF | 50 Hz PDF

R222

Series

75.0

28.6

0.98

60 Hz PDF | 50 Hz PDF

R252

Parallel

69.8

25.1

2.06

60 Hz PDF | 50 Hz PDF

R252

Series

75.0

28.9

1.12

60 Hz PDF | 50 Hz PDF

R272

Parallel

75.0

25.3

2.37

60 Hz PDF | 50 Hz PDF

R272

Series

75.0

29.2

1.24

60 Hz PDF | 50 Hz PDF

 

R-Series Double Head — Metric Units

Model #

Head connection

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge*)

Max flow (SLPM)

Performance curves

R202

Parallel

3.20

789

48.5

60 Hz PDF | 50 Hz PDF

R202

Series

5.17

958

28.7

60 Hz PDF | 50 Hz PDF

R222

Parallel

3.79

812

51.1

60 Hz PDF | 50 Hz PDF

R222

Series

5.17

968

27.8

60 Hz PDF | 50 Hz PDF

R252

Parallel

4.81

850

58.4

60 Hz PDF | 50 Hz PDF

R252

Series

5.17

978

31.8

60 Hz PDF | 50 Hz PDF

R272

Parallel

5.17

856

67

60 Hz PDF | 50 Hz PDF

R272

Series

5.17

988

35

60 Hz PDF | 50 Hz PDF

 

R-Series Quad Head Dia-Vac®

Important: Maximum pressure, maximum vacuum and maximum flow represent separate operating limits and should not be interpreted as simultaneous performance values. Published figures are averaged test results; actual pump performance depends on the application.

Flow Averages

(Please click on individual Model # for actual performance curves)

R-Series Quad Head — US Units

Model #

Head connection

Max pressure (PSIG)

Ultimate vacuum (inHg gauge)

Max flow (SCFM)

Performance curves

R224

Parallel

70

24.8

3.53

60 Hz PDF | 50 Hz PDF

R224

Series

75

29.4

0.98

60 Hz PDF | 50 Hz PDF

R224

Series/Parallel

75

28.6

1.89

60 Hz PDF | 50 Hz PDF

R254

Parallel

75.0

24.9

3.8

60 Hz PDF | 50 Hz PDF

R254

Series

75.0

29.4

1.1

60 Hz PDF | 50 Hz PDF

R254

Series/Parallel

75.0

29.1

2.0

60 Hz PDF | 50 Hz PDF

 

R-Series Quad Head — Metric Units 

Model #

Head connection

Max pressure (bar gauge)

Ultimate vacuum (mbar gauge*)

Max flow (SLPM)

Performance curves

R224

Parallel

4.80

839

100

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series

5.17

995

27.8

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R224

Series/Parallel

5.17

968

53.7

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Parallel

5.17

839

108

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series

5.17

995

31.4

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

R254

Series/Parallel

5.17

985

57.1

60 Hz PDF | 50 Hz PDF | 60 Hz deep vacuum | 50 Hz deep vacuum

 

R-Series pumps are available with different eccentric sizes and single-, double- and quad-head configurations. This allows the pump to be configured for different combinations of vacuum and flow.

Single-head configurations provide a compact solution across a range of vacuum and flow requirements. Multi-head configurations can be arranged to increase vacuum or increase flow, depending on the system design.

For accurate pump selection, compare the required operating point with the performance data for the individual model rather than relying on maximum vacuum or free-flow values alone.

R-Series pumps are designed for gas sampling and analysis systems requiring dependable sample transport and configurable vacuum performance. 

Continuous Emissions Monitoring

Support sample transport in CEMS and other emissions monitoring systems. 

Process Gas Analysis

Move process gas samples through sampling lines and system components to downstream analytical equipment. 

Environmental Monitoring 

Support gas sampling systems used for environmental and air monitoring applications. 

Analytical and Laboratory Sampling 

Provide configurable vacuum and flow for gas analysis and instrument sampling systems. 

Configurable Vacuum and Flow

Choose from multiple eccentric sizes and head configurations to meet different vacuum and sample flow requirements.

Single- and Multi-Head Configurations

Single-, double- and quad-head configurations provide flexibility for applications requiring different combinations of vacuum and flow.

Configurable Wetted Materials

Select from available head and diaphragm materials based on the requirements of the sampled gas and application.

Multiple Motor Options

Configure the pump with motor options appropriate for the installation and operating environment. 

How to Order Your R-Series Dia-Vac® Pump

Ready to order an R-Series pump? Getting started is simple.

SIMPLE PROCESS LINE

Select your pump → Request a Quote → Talk to our Sales Team

Choose the model or configuration that best matches your requirements, then click Request a Quote and tell us which pump you're interested in. Our Sales Team will contact you to confirm the specifications, discuss your application and help finalize your order.

ALTERNATIVE PATH

Not sure which pump you need? You don't have to choose a model first. Click Ask a Question to connect with one of our experts. We'll help you identify the R-Series configuration that best fits your application.

 

R-Series Dia-Vac® pumps are available with a variety of head configurations, wetted materials, motor specifications, and optional features to meet your application requirements.

Use the ordering guide below to explore the available configurations. When requesting a quote, provide your preferred specifications or describe your application requirements so our team can help identify a suitable pump configuration.

How to Configure Your Pump

  1. Choose your pump capacity

    Select the eccentric size and number of heads based on your required performance.

  2. Select wetted materials

    Choose head and diaphragm materials suitable for the gas being handled.

  3. Specify motor requirements

    Identify the appropriate motor type, voltage and frequency for your installation.

  4. Review additional options

    Consider any special requirements, such as an elevated head or alternative housing orientation.

  5. Request a quote

    Share your selections with the Air Dimensions team to confirm compatibility, availability and pricing.

Understanding the Ordering Codes

Each section of the ordering guide represents a different pump configuration characteristic, including capacity, materials, motor specifications and optional features.

The available codes help identify the required specifications when discussing your pump configuration with our team.

Please note: Not all combinations of components and options may be available or compatible. Contact Air Dimensions to confirm the correct configuration and complete model number before ordering.

 

Category

Selection

Available codes and descriptions

Capacity

Pump style

B — Standard

Capacity

Eccentric size

27; 25; 22; 20; 18; 15; 12; 10; 08; 06

Capacity

Number of heads

1; 2; 4; 8

Wetted materials

Head material

A — Alum; B — Tef/Alum; F — 316ss; G — 316ss (TefCo); H — Hastelloy C; J — Hast. C (TefCo); L — Silconert®316ss; P — Electro Polish; T — Solid Teflon

Wetted materials

Diaphragm

E — Encap Tef/EPDM*; N — EPDM; P — All Teflon; T — Tef/EPDM; V — Viton

Motor

Motor type

D — Air; N — XP(Gr CD) 1/2 HP; Q — ATEX/IECEx (IIC) .55kW; R — XP Gr.B,C,D (UL) 1/6 HP; V — XP (C,D) 1HP; Y — ATEX/IECEx (IIC) .37kW

Motor

Voltage

A — 115; B — 230; D — 220/380; E — 230/460; X — N/A

Motor

Frequency

0 — N/A; 1 — 60 1Ph; 2 — 50 1Ph; 3 — 60 3Ph; 4 — 50 3Ph

Options

Additional options

A — 416ss Valve Discs; D — Double Diaphragm; E2 — Extended Head; L — Elevated Head; P — Epoxy coatfor offshore; M8 — Heated Steam (XP); X — Rotate Housing 90° CW; Y — Rotate Housing 90° CCW; Z — Rotate Housing 180°

 

REACH OUT TO US